Cubierta y fachada
Panel sándwich PIR/PUR/lana de roca, chapa trapezoidal y ondulada, chapa colaborante, perfil teja, junta alzada.
Panel sándwichPIR, PUR, rockwool and EPS roof and wall panels, 40–200 mm, EN 14509.Fabricado en Dilovası
Panel sándwich de cubierta5-rib (trapezoidal) roof panels with PIR / PUR / rockwool core, 40–150 mm, overlap joint, slopes from 5 %.De stock
Panel sándwich de fachadaFlat, micro-ribbed or lined wall panels with PIR / PUR / rockwool core 40–150 mm, tongue-and-groove joint, visible or hidden fix.De stock
Panel sándwich PIRPolyisocyanurate-core roof and wall panels — λ 0.022 W/mK, B-s1,d0, 40–200 mm — the best insulation per millimetre.De stock
PUR sandwich panel (EN)Polyurethane-core roof and wall panels — λ 0.024 W/mK, 40–120 mm — the economy foam core for sheds, camps and unheated buildings.De stock
EPS sandwich panel (EN)Expanded-polystyrene-core roof and wall panels 50–200 mm — the lowest-cost insulated panel for partitions, camps and mild climates.De stock
Rockwool sandwich panel (EN)Non-combustible mineral-wool-core roof and wall panels — A2-s1,d0, EI 30–120 fire walls, 50–200 mm, acoustic Rw 30–34 dB.De stock
Cold room panel (EN)PIR cold-store and freezer panels 80–200 mm with flat food-grade skins, cam-lock or tongue-and-groove joints, for 0 °C to −40 °C.De stock
Trapezoidal & corrugated sheet (EN)27/150, 38/151, 45/333 profiles in galvanized, PPGI and aluzinc.Fabricado en Dilovası
Chapa ondulada de cubierta 18/76Classic sinusoidal corrugated (sinus) galvanized and coloured roofing sheet, 18 mm × 76 mm wave, 0.40–0.70 mm.De stock
Chapa trapezoidal 27/150Light 27 mm trapezoidal profile (T27) for walls, roofs on close purlins and liner sheet — galvanized or coloured, 0.40–0.60 mm.De stock
Chapa trapezoidal 38/151The standard 38 mm roof profile (T38) for industrial roofs at 2–3 m purlin spacing — galvanized or coloured, 0.40–0.70 mm.De stock
Trapezoidal sheet 45/333 (EN)Deep 45 mm three-rib profile for 3–4 m purlin spacing, long-span roofs and light decking — 0.50–1.0 mm.De stock
Galvanized trapezoidal sheet (EN)Plain hot-dip galvanized (GI) trapezoidal roofing and cladding sheet in 27/150, 38/151 and 45/333, Z100–Z275, 0.40–0.70 mm.De stock
Chapa trapezoidal PPGIColour-coated (pre-painted galvanized) trapezoidal roofing and cladding in 27/150, 38/151 and 45/333 — RAL colours, PE / SMP / PVDF, 0.40–0.70 mm.De stock
Composite floor deck (EN)Deck profile for concrete slabs, 0.70–1.20 mm.Fabricado en Dilovası
Tile-profile sheet (EN)Roll-formed metal roof tile in RAL colours.Fabricado en Dilovası
Standing seam roofing (EN)Snap-lock and mechanically seamed panels.Fabricado en Dilovası
Aluminium trapezoidal sheet (EN)Aluminium 27/150, 38/151, 45/333 profiles rolled from 3105 H44 coil 0.60–1.00 mm — mill, stucco or coated; coastal and chemical roofs.De stock
Aluminium corrugated sheet (EN)Sinusoidal 18/76 in aluminium 0.50–1.00 mm — no rust at cut edges, curves to R 1.5 m; jacketing, coastal and rural roofs.De stock
Aluminium standing seam roof (EN)Snap-lock 25 and double-lock 65 mm (Kalzip-type) panels from 3004 / 3005 H44, pitch from 1.5°, curved and site-rolled to 30 m.De stock
Aluminium sandwich panel (EN)PIR, PUR and rockwool panels 40–200 mm with coil-coated aluminium skins — coastal, food, chemical and cold-store walls and roofs.De stockLa altura de la onda es una decisión estructural, no estética
El canto de la onda que aparece en el nombre del perfil es el número que decide cuánto puede salvar la chapa. Una chapa ondulada 18/76 tiene 18 mm de canto y pide correas separadas en torno a 1,0 m; una trapezoidal 45/333 tiene 45 mm y salva 2,5 m o más con el mismo espesor. Elegir primero el perfil y después la separación de correas es el error habitual, y cuesta más en acero de lo que el perfil llega a ahorrar.
El canto cambia además la superficie cubierta. Una onda más profunda pliega más bobina dentro del perfil, de modo que una bobina de 1.250 mm cubre 1.150 mm como trapecio bajo y 1.000 mm como trapecio profundo: un 13 % de diferencia en número de chapas para la misma cubierta.
Todo en cubierta y fachada de un vistazo
| Producto | Rango | Norma | Disponibilidad |
|---|---|---|---|
| Sandwich panel | EN 14509 CE | EN 14509 CE | Made in our plant |
| Roof sandwich panel | 5-rib outer skin | PIR · PUR · rockwool | Made in our plant |
| Wall sandwich panel | Flat · micro-rib · lined | PIR · PUR · rockwool | Made in our plant |
| PIR sandwich panel | λ 0.022 W/mK | B-s1,d0 / B-s2,d0 | Made in our plant |
| PUR sandwich panel | λ 0.024 W/mK | 40 kg/m³ closed cell | Made in our plant |
| EPS sandwich panel | λ 0.036 W/mK | 15–20 kg/m³ | Made in our plant |
| Rockwool sandwich panel | A2-s1,d0 non-combustible | EI 30–120 walls | Made in our plant |
| Cold room panel | PIR λ 0.022 | 80–200 mm | Made in our plant |
| Trapezoidal & corrugated roofing sheet | 18/76 · 27/150 · 38/151 · 45/333 | 0.30 – 0.70 mm | Made in our plant |
| Corrugated roofing sheet 18/76 | 18 mm × 76 mm wave | Cover 1 000 mm | Made in our plant |
| Trapezoidal sheet 27/150 | 27 mm rib · 150 mm pitch | Cover 1 050 mm | Made in our plant |
| Trapezoidal sheet 38/151 | 38 mm rib · 151 mm pitch | Cover 906 mm | Made in our plant |
| Trapezoidal sheet 45/333 | 45 mm rib · 333 mm pitch | Cover 1 000 mm | Made in our plant |
| Galvanized trapezoidal sheet | Z100 · Z140 · Z275 | 27/150 · 38/151 · 45/333 | Made in our plant |
| PPGI trapezoidal sheet | 6 stock RAL colours | PE · SMP · PVDF | Made in our plant |
| Composite floor deck | 50/1000 · 60/940 · 75/750 | 0.70 – 1.20 mm · S350GD+Z275 | Made in our plant |
| Tile-profile roofing sheet | 350 mm step · 1 100 / 1 180 cover | 0.40 – 0.60 mm PPGI / PPGL | Made in our plant |
| Standing seam roofing | Snap-lock 25 · double-lock 25 / 38 mm | Pan 300 – 600 mm | Made in our plant |
| Aluminium trapezoidal sheet | EN AW-3105 / 3003 H44 | 0.60–1.00 mm | Made in our plant |
| Aluminium corrugated sheet | 18 × 76 mm sinus | Cover 1 000 mm | Made in our plant |
| Aluminium standing seam roof | EN AW-3004 / 3005 H44 | 0.70–1.20 mm | Made in our plant |
| Aluminium sandwich panel | EN 14509 · CE | EN 14509 · CE | Made in our plant |
Los rangos son el envolvente que tenemos en stock o perfilamos, no una tolerancia. La ficha de producto incluye la tabla de medidas completa, los pesos y la norma aplicable.
Preguntas frecuentes
¿Qué espesor de chapa de cubierta debo usar?
De 0,40 a 0,50 mm cubre vivienda y nave ligera con correas a 1,0–1,5 m. Suba a 0,60 o 0,70 mm para separaciones mayores, para sobrecarga de nieve o donde el mantenimiento vaya a pisar la cubierta.
¿Qué es el ancho útil?
El ancho que una chapa cubre realmente una vez descontado el solape lateral, que siempre es menor que el ancho de la bobina de la que se perfiló. Una bobina de 1.250 mm suele dar entre 1.000 y 1.150 mm de cubrición según la profundidad del perfil.
¿Panel sándwich o chapa más aislamiento?
Panel para cualquier edificio climatizado: se monta en una sola pasada, sella mejor y lleva ya unidos su aislamiento y su barrera de vapor. Chapa y aislamiento por separado sale más barato en material y tiene sentido en estructuras sin climatizar o en una recubrición sobre correas existentes.
¿Qué núcleo de panel sándwich elijo?
PIR por la mejor combinación de comportamiento térmico y frente al fuego, EPS cuando manda el presupuesto y la exigencia de fuego es modesta, lana de roca cuando hay una clasificación de fuego obligatoria. A igual espesor, la lana de roca pesa aproximadamente el doble que el PIR.
¿Cuántas chapas necesita una cubierta?
Divida la superficie entre ancho útil por longitud de chapa y redondee hacia arriba; después añada un 3–5 % de despiece. Un faldón de 240 m² con chapas de 6 m que cubren 1.000 mm necesita 40 chapas antes del despiece.